Dragino DR-ECK10.0 EC (Conductivity) Sensor

Water electrical conductivity (EC) sensor for Dragino WQS-LB or WQS-NB nodes. RS485 (9600 baud), range K=10 to 20000 µS/cm, 10 µS/cm resolution, ±1% FS accuracy. Built-in temperature measurement (-20 to 60 °C) plus salinity and TDS conversion. IP68, 5 m cable, 0.6 MPa pressure resistance.

SKU:

incl. VAT142,68 excl. VAT119,90 plusShipping Costs

3 in stock

Related items

Dragino WQS-LB LoRaWAN Wasserqualitätssensorknoten

Dragino WQS-LB Wasserqualität kaufen | Kilo Electronics

incl. VAT70,20 excl. VAT58,99 plusShipping Costs

8 in stock

lps8 v2 dragino front

Dragino LPS8v2 with 4G LoRaWAN Gateway (EU868)

incl. VAT224,79 excl. VAT188,90 plusShipping Costs

3 in stock

dragino wqs-nb

Dragino WQS-NB NB-IoT Water Quality Sensor Node

incl. VAT73,78 excl. VAT62,00 plusShipping Costs

1 in stock

RAKwireless WisGate Edge Pro Outdoor LoRaWAN Gateway RAK7289CV2 (16 Channel) LTE

Outdoor LoRaWAN Gateway 16-Channel – RAKwireless WisGate Edge Pro RAK7289V2 (868 MHz)

SKU: 715122 incl. VAT581,91 excl. VAT489,00 plusShipping Costs

3 in stock

Grand total: incl. VAT0,00 excl. VAT0,00 plusShipping Costs
Product Description Technical Details

The Dragino DR-ECK10.0 is a professional EC (electrical conductivity) probe for measuring how conductive water is—one of the fastest practical indicators that salinity, mineral content, or dissolved ions have changed. That makes EC a high-value signal in systems where chemistry must stay consistent, or where salinity shifts can damage crops, equipment, or biological systems. The probe is designed to connect to Dragino WQS-LB and WQS-NB nodes and outputs data via RS485.

Industries and strong real-world use cases:

Irrigation & agriculture: Using EC to manage salinity risk in well/surface/blended water and to prevent yield loss or soil salinization.

Greenhouse / hydroponics / fertigation: EC is often the primary control metric for nutrient strength and recipe consistency.

Aquaculture, RAS, and aquariums: Monitoring salinity and mineral balance, especially where evaporation, water changes, or dosing can shift water chemistry.

Industrial water, cooling towers, and boilers: EC for concentration control, optimizing blowdown, and catching unexpected chemistry changes in closed loops.

Water reuse / treatment / intake monitoring: EC as a reliable trend signal for variable feedwater quality.

Wastewater (properly framed): EC is commonly used as an event/diagnostic indicator—for spotting salty industrial discharges, infiltration, or process-water ingress—rather than being the “main” compliance parameter.

The probe also provides salinity and TDS conversion, which is often what operators track for thresholds and reporting. With IP68 sealing, 0.6 MPa pressure resistance, and a 5 m cable, it’s built for long-term in-water deployments.

Manufacturer Dragino
Model DR-ECK10.0
Type EC / conductivity sensor
Compatibility Dragino WQS-LB, Dragino WQS-NB
Interface RS485 (9600 baud)
EC range K=10 – 20000 µS/cm
EC resolution 10 µS/cm
EC accuracy ±1% FS
Functions Salinity & TDS conversion
Temperature range (measurement) -20 – 60 °C
Temperature resolution 0.1 °C
Temperature accuracy ±0.5 °C
Operating temperature 0 °C to +60 °C
Power supply 7–30 V DC
Power consumption ≤ 0.5 W
IP rating IP68
Pressure resistance 0.6 MPa
Cable length 5 m